Certain customers prefer using Ethernet ports for data transmission instead of the TX900’s three data ports. This article provides instructions on how to do that.
This document applies to the models below, і т.д..
-
10W PA 150KM бортовий канал відеоданих БПЛА бездротової передачі приймач широкосмугової тактичної ручки -
22км 55 км 80 км 100 км 150 км міжміський бездротовий відеопередавач приймач передача трансивер PA 2W 5W 10W -
Двосторонній бездротовий БПЛА Відеодані RC Control Link модуль Двонаправлений трансивер Передавач-приймач Vcan1681
The TX900 has three serial ports, two of which (D2 and D3) are used for wireless network access through IP addresses. The system includes a built-in serial port server allowing D2 and D3 ports to convert serial data over networks using TCP or UDP protocols. The D2 and D3 serial ports on the TX900 are identified by their port numbers.
Using the TCP protocol, the external device (комп'ютер) needs to create a TCP client, which can be used after connecting to the target TX900. The external device (комп'ютер) sends TCP data to the target TX900, which converts this data into serial port data and sends it out. The target TX900 will actively send this data to the TCP client upon receiving the serial port data.
Using the UDP protocol, external devices (computers) need to create a UDP service, and the local and remote port numbers of the UDP service need to correspond one-to-one with the “target port” і “порт прослуховування” of the target TX900. The external device (комп'ютер) sends UDP data to the target TX900, which converts this data into serial port data and sends it out. When the target TX900 receives serial port data, it actively sends this data to the “target port” of the “target IP”, where the “target IP” must be the IP address of the external device (комп'ютер).
TX900 configuration
Примітка: Changing TX900 parameters in the web UI requires restarting TX900 to take effect.
приклад 1: Serial port 2 з TX900-Access Node (IP адресу: 192.168.1.12) is required to communicate with the TCP client of the computer (IP адресу: 192.168.1.50) connected to the remote network port, as shown in the following figure.

In the web UI of TX900-Access Node (IP адреса 192.168.1.12), set the network IP parameters:
Локальний IP: TX900-Access Node’s own IP address (напр. 192.168.1.12)
Target IP: опціональний

In the web UI of TX900-Access Node, select Serial Port->Serial Port 2->Protocol Select “TCP”, and then click “добре”.

After clicking “добре”, the interface will display:

When creating a TCP client for a computer connected to a remote network (192.168.1.50), its remote IP address needs to be configured as the IP address of TX900-Access Node (192.168.1.12), and the port number needs to be configured as the TCP parameter “порт прослуховування” (такі як 2002) corresponding to the serial port of TX900-Access Node (such as serial port 2). Example of remote computer TCP client configuration:

приклад 2: The computer (IP адресу: 192.168.1.51) that requires послідовний порт 3 з TX900-Access Node to connect to the remote network port uses UDP protocol for communication, as shown in the following figure.

In the web UI of TX900-Access Node, set the network IP parameters:
Локальний IP: TX900-Access Node’s own IP address (напр. 192.168.1.12)
Target IP: The IP address of the computer connected to the remote network port (напр. 192.168.1.51), which can also be left unconfigured. Configure the target IP address in the specific configuration of serial port 3 below.

In the web UI of TX900-Access Node, select Serial Port->Serial Port 3->Protocol Select UDP, and then click OK.

After clicking “добре”, the interface will display:

Fill in the IP address of the target computer in sequence (assuming 192.168.1.51), the target port is the UDP local port number of the target computer (assuming 8090), and the listening port is the UDP remote port number of the target computer (assuming 8090).
When creating a UDP client on the target computer (192.168.1.51), its target IP address needs to be configured as the IP address of Access Node (192.168.1.12), the remote port number needs to be configured as the listening port of Access Node (assuming 8090), and the local port number needs to be configured as the target port of Access Node (assuming 8090). As shown in the following example:

приклад 3: A computer (IP адресу: 192.168.1.55) that requires послідовний порт 2 з TX900-Access Node to communicate with the remote network port via TCP client, while also communicating з послідовний порт 2 з дистанційний TX900-Center Node, as shown in the following figure:

In the web UI of TX900-Access Node, set the network IP parameters:
Локальний IP: TX900-Access Node’s own IP address (напр. 192.168.1.12)
Target IP: опціональний

In the web UI of TX900-Access Node, select Serial Port->Serial Port 2->Protocol Select “Обидва”, and then click “добре”.

After clicking “добре”, the interface will display:

The target IP in the UDP parameters is set to the IP address 192.168.1.11 of the remote TX900-Central Node. The target port is set to be consistent with the D2 serial port listening port of the remote TX900-Central Node, and the listening port is set to be consistent with the D2 serial port target port of the remote TX900-Central Node.
The configuration of serial port 2 for remote TX900-Central Node (192.168.1.11) is as follows, corresponding to TX900-Access Node:

When creating a TCP client for a computer connected to a remote network (192.168.1.55), its remote IP address needs to be configured as the IP address of TX900-Access Node (192.168.1.12), and the port number needs to be configured as the TCP parameter “порт прослуховування” (такі як 2002) corresponding to the serial port of TX900-Access Node (such as serial port 2).





задавати питання
Дякуємо за вашу відповідь. ✨