IP MESH Ad Hoc nätverk användarhandbok

IP MESH Ad Hoc nätverk användarhandbok

      Version number: iVcan-20230606

Brief introduction

  • Our Ad hoc network communication radio station, as a mobile self-organizing network, supports any network topology.
  • Unlike traditional wireless networks, it is a wireless broadband system with no center, distribuerad, multi-hop relä, dynamisk routing, stark osårbarhet, and good scalability.
  • Some routing protocols complete the wireless communication between nodes through wireless multi-hop forwarding.
  • Ett ad hoc distribuerat trådlöst bredbandsnätverksöverföringssystem med ett effektivt MAC-lageröverföringsprotokoll och ett tvålagers routingprotokoll.
  • All nodes are completely equal, without any infrastructure, and can quickly build a dedicated self-organizing network between mobile nodes, provide instant adaptive communication, have excellent broadband performance, and support the real-time transmission of multimedia information such as video coding and audio coding.
  • The system technology has the advantages of strong anti-interference ability, hög spektrumeffektivitet, långt överföringsavstånd, anti-blekningsförmåga, och stark diffraktionsförmåga.
  • Den kan realisera trådlösa tvåvägsdataöverföringsfunktioner i realtid och högkvalitativt i komplexa och icke-line-of-sight-miljöer.

Technical Features

IP MESH Ad Hoc network
IP MESH Ad Hoc network
  • There is no need to set up a central station and complex system configuration. After the site is powered on, det kommer automatiskt att bilda ett nätverk, och kommunikationen kan startas i “sekunder”;
  • Godtycklig topologi, multi-hop relä, vidarebefordran av relä;
  • De logiska attributen för varje nod kan konfigureras flexibelt;
  • För närvarande, the same frequency network can support the interconnection of ≥32 nodes;
  • Kanalen är krypterad med AES;
  • The system data bandwidth peak value is 90Mbps;
  • Strong anti-interference ability, hög spektrumeffektivitet, långt överföringsavstånd, anti-interferens
  • Strong falling ability and diffraction ability

Tekniska parametrar

  • Kommunikationsfrekvens: 1412~1452MHz, adjustable in 5MHz steps;
  • Överföringseffekt: 2*30dBm (2*1W), 1dBm steg justerbar。
  • Bandbreddsläge: 5 / 10 / 20 MHz;
  • modulationsförfarandet: multibärar TDD-COFDM;
  • Bärvågsmodulering: BPSK/QPSK/16QAM/64QAM (adaptiv eller fixerad);
  • Ta emot känslighet: -98dBm @ 10MHz;
  • Communication distance: 30km (ground-air/air-air line-of-sight), 8km (ground-ground line-of-sight);
  • Communication rate: peak 90Mbps (adaptive);
  • Sändningsfördröjning: Single jump about 2ms
  • Multi-hop capability: upp till 8 video jumps;
  • Start time: ≤25S;
  • Nätverksåtkomsttid: mindre än 1 andra;
  • Routing switching: mindre än 1 andra;
  • data~~POS=TRUNC gränssnitt~~POS=HEADCOMP: nätverksport x 2, RS232 x 2;
  • Energiförbrukning: 2~8W
  • Protection level: IP65;
  • Arbetstemperatur: -40~ + 70 ℃;
  • Mått: längd: 72.8mm*width 47.3mm*height 17.9mm
  •  Vikt: 78g

Software operation Instructions

Support 5M, 10M, and 20M bandwidth, real-time graphical interface display, real-time map indication, etc.

The software disables DHCP by default, and the default IP address is 192.168.17.1 If you forget the address, please connect the 9th pin of the 26PIN cable to the ground to reset the parameters.

Enter the IP address of the module in the browser, and the default username and password are both admin. It takes about 20s for the module to connect to the network from power-on. The recommended browser is Chrome.

After entering, it defaults to simple mode, click expert mode to unlock more settings, suitable for professional debugging.

Status section:

IP MESH Ad Hoc network user guide 1

Översikt:

IP MESH Ad Hoc network user guide 2

Topology map: (automatic refresh is turned off by default to save bandwidth, you can check automatic refresh)

IP MESH Ad Hoc network user guide 3

Check only the display path, you can know the direct jump point relationship of each module

IP MESH Ad Hoc network user guide 4

Check the details to judge the data connection status of each module. These are displayed dynamically in real time

IP MESH Ad Hoc network user guide 5

Click Details: You can know the specific situation of each module directly:

IP MESH Ad Hoc network user guide 6

Terminal state:

IP MESH Ad Hoc network user guide 7

Ad hoc network: You can remark the name, självklart, it can also be operated in the terminal state.

IP MESH Ad Hoc network user guide 8

Spectrum scanning: Check the interference of each frequency band. Självklart, the frequency bands of different modules are purchased, and the scanning frequency bands are different.

IP MESH Ad Hoc network user guide 9

Map: (Självklart, to know the location information of each terminal, GNSS modules such as GPS or Beidou need to be installed)

Support tile maps, image maps, network maps, etc.

IP MESH Ad Hoc network user guide 10

Configuration section

Läge: 1. MESH node or bridge configuration

IP MESH Ad Hoc network user guide 11

2. Wireless configuration:

IP MESH Ad Hoc network user guide 12

2.1 Transmission power configuration, the power of different products purchased is different.

kanal bandbredd: 5M 10M 20M 40M

Kanal: Different channels are used to purchase different products

The coverage distance (meter) needs to be filled in according to the actual situation. If it is set to 3000 meter, it is impossible to actually run to 5000 meter.

Number of Antennas 2

Fixed MCS rate: Can be set to off for automatic selection. If you want stable transmission, it is recommended to set the manual, räckvidd (MCS0 to MCS15)

Bandbredd, Modulation, Betygsätta

Limit MCS rate: It is recommended to enable it. After enabling it, if the fixed rate is MCS4, the software will automatically select the best modulation method from MCS0 to MCS4 during the test.

5M10M20M40M
MCS0BPSK 1/21.7M3.3m6.5M13.5M
MCS1QPSK 1/23.2m6.5M13m27m
MCS2QPSK 3/44.8m9.8m19.5M40.5M
MCS316QAM 1/26.5M13m26M54M
MCS416QAM 3/49.7M19.5M39M81M
MCS564QAM 2/313m26M52m108M
MCS664QAM 3/414.5M29M58.5M121M
MCS764QAM 5/616M32.5M65m135M
MCS8BPSK 1/23.2m6.5M13m27m
MCS9QPSK 1/26.5M13m26M54M
MCS10QPSK 3/49.7M19.5M39M81M
MCS1116QAM 1/213m26M52m108M
MCS1216QAM 3/419.5M39M78M162M
MCS1364QAM 2/326M52m104M216M
MCS1464QAM 3/429M58.5M117M243M
MCS1564QAM 5/632.5M65m130M270M

From MCS0 to MCS7, two wireless ports send the same data in order to improve stability during the movement.

From MCS8 to MCS15, the two wireless ports send different data, which can make the rate X2

If it is in a mobile state, it is recommended to use BPSK or QPSK to transmit data. 16QAM and 64QAM are suitable for use with fixed transmission.

If MCS8 to MCS15 is used, it is recommended that the antennas of the two ports be 90 degrees from each other, till exempel, one is vertical and the other is horizontal.

If drones are used, MCS0 to MCS2 is recommended.

The greater the bandwidth, the lower the sensitivity. The same goes for modulation.

above rate unit bps

3. Nätverk:

IP MESH Ad Hoc network user guide 13

4. User management:

IP MESH Ad Hoc network user guide 14

5. Systemet

IP MESH Ad Hoc network user guide 15

6. Tools Configure serial port, GPS/Beidou/GNSS, 4G/5G access, and other parameters

IP MESH Ad Hoc network user guide 16

6.1 Multi-device management, in the upper right corner, you can log in and manage users remotely, and it is also a real-time dynamic interface display or map display.

IP MESH Ad Hoc network user guide 17
IP MESH Ad Hoc network user guide 18

6.2 Serial port software settings:

IP MESH Ad Hoc network user guide 19

Select Expert Mode, Verktyg, and UART Interface.

IP MESH Ad Hoc network user guide 20

choose new

IP MESH Ad Hoc network user guide 21

Uppmärksamhet, if you use the serial port to transmit serial data, you have to choose ttyS0 (COM1 of hardware) and ttyUSB0 (COM2 of hardware), ttyATH0 is invalid, läge: network

baudhastighet 115200, stoppbit 1, parity none.

namn 1, protocol UDP, IP address, 192.168.55.100 (the IP address here is the IP address of the other device, till exempel, input the IP of the computer for the computer, and input the IP of the device for the device).

Hamn 20005, 20003. Choose a port number

The computer’s IP is set to a fixed 192.168.17.100

IP MESH Ad Hoc network user guide 22

Short the TX RX pins of COM1 and COM2 of the device.

IP MESH Ad Hoc network user guide 23

Use the TCP UDP test tool to fill in the IP and port of the device.

Send it to loop back the data.

Lämna ett svar

Din e-postadress kommer inte att publiceras. behövliga fält är markerade *

Upptäck mer från iVcan.com

Prenumerera nu för att fortsätta läsa och få tillgång till hela arkivet.

Fortsätt läsa

Behöver hjälp på WhatsApp?