Operate guide for Vcan1401-Mesh Ad hoc network communication module

Mesh Ad hoc network communication module

1. Brief introduction of ad hoc network communication module

As a mobile self-organizing network, Vcan1401-Mesh supports any network topology. Unlike traditional wireless networks, it is a wireless broadband system with no center, distributed, multi-hop relay, dynamic routing, strong invulnerability and good scalability. It uses its own routing protocol internally to complete the wireless communication between nodes through wireless multi-hop forwarding. An ad hoc distributed broadband wireless network transmission system with an efficient MAC layer transmission protocol and a two-layer routing protocol. All nodes are completely equal, without any infrastructure, and can quickly build a dedicated self-organizing network between mobile nodes, provide instant adaptive communication, have excellent broadband performance, and support the real-time transmission of multimedia information such as video coding and audio coding. The system technology has the advantages of strong anti-interference ability, high spectrum efficiency, לאַנג טראַנסמיסיע ווייַטקייט, anti-fading ability, and strong diffraction ability. It can realize real-time and high-quality wireless two-way data transmission functions in complex and non-line-of-sight environments.

Vcan1401-Mesh series technical features

*There is no need to set up a central station and complex system configuration. After the site is powered on, it will automatically form a network, and the communication can be started in “סעקונדעס”;

* Arbitrary topology, multi-hop relay, relay forwarding;Operate guide for Vcan1401-Mesh Ad hoc network communication module 1

* The logical attributes of each node can be flexibly configured;

* יצט, the same frequency network can support the interconnection of ≥32 nodes;

* The channel is encrypted with AES;

* The system data bandwidth peak value is 90Mbps;

* שטאַרק אַנטי-ינטערפיראַנס פיייקייַט, high spectrum efficiency, לאַנג טראַנסמיסיע ווייַטקייט, אַנטי-ינטערפיראַנס

Strong falling ability and diffraction ability

2. טעכניש פּאַראַמעטערס

  • Communication frequency: 1412~1452MHz, adjustable in 5MHz steps;
  • טראַנסמיסיע מאַכט: 2*30דבם (2*1ד), 1dBm step adjustable
  • Bandwidth mode: 5 / 10 / 20 מהז;
  • מאָדולאַטיאָן אופֿן: multi-carrier TDD-COFDM;
  • Carrier modulation: BPSK/QPSK/16QAM/64QAM (adaptive or fixed);
  • באַקומען סענסיטיוויטי: -98dBm @ 10MHz;
  • Communication distance: 30קילאמעטער (ground-air/air-air line-of-sight), 8קילאמעטער (ground-ground line-of-sight);
  • Communication rate: peak 90Mbps (adaptive);
  • טראַנסמיסיע פאַרהאַלטן: Single jump about 2ms
  • Multi-hop capability: ביז צו 8 video jumps;
  • Start time: ≤25S;
  • נעץ אַקסעס צייט: ווייניגער ווי 1 סעקונדע;
  • רוטינג סוויטשינג: ווייניגער ווי 1 סעקונדע;
  • דאַטן צובינד: נעץ פּאָרט רענטגענ 2, RS232 x 2;
  • מאַכט קאַנסאַמשאַן: 2~8W
  • Protection level: IP65;
  • ארבעטן טעמפּעראַטור: -40~ 70 ℃;
  • דימענסיאָנס: לענג: 72.8mm*width 47.3mm*height 17.9mm
  •  וואָג: 78ג

2. Software operation instructions

Support 5M, 10ב, and 20M bandwidth, real-time graphical interface display, real-time map indication, אאז"ו ו.

The software disables DHCP by default, and the default IP address is 192.168.17.1 If you forget the address, please connect the 9th pin of the 26PIN cable to the ground to reset the parameters.

Enter the IP address of the module in the browser, and the default username and password are both admin. It takes about 20s for the module to connect to the network from power-on. The recommended browser is Chrome.

After entering, it defaults to simple mode, click expert mode to unlock more settings, suitable for professional debugging.

3. Status section:

Operate guide for Vcan1401-Mesh Ad hoc network communication module 2

איבערבליק:

Operate guide for Vcan1401-Mesh Ad hoc network communication module 3

Topology map: (automatic refresh is turned off by default to save bandwidth, you can check automatic refresh)

Operate guide for Vcan1401-Mesh Ad hoc network communication module 4

Check only the display path, you can know the direct jump point relationship of each module

Operate guide for Vcan1401-Mesh Ad hoc network communication module 5

Check the details to judge the data connection status of each module. These are displayed dynamically in real time

Operate guide for Vcan1401-Mesh Ad hoc network communication module 6

Click Details: You can know the specific situation of each module directly:

Operate guide for Vcan1401-Mesh Ad hoc network communication module 7

Terminal state:

Operate guide for Vcan1401-Mesh Ad hoc network communication module 8

אַד האָק נעץ: You can remark the name, זיכער, it can also be operated in the terminal state.

Operate guide for Vcan1401-Mesh Ad hoc network communication module 9

Spectrum scanning: Check the interference of each frequency band. זיכער, the frequency bands of different modules are purchased, and the scanning frequency bands are different.

Operate guide for Vcan1401-Mesh Ad hoc network communication module 10

Map: (זיכער, to know the location information of each terminal, GNSS modules such as GPS or Beidou need to be installed)

Support tile maps, image maps, network maps, אאז"ו ו.

Operate guide for Vcan1401-Mesh Ad hoc network communication module 11

Configuration section:

מאָדע: 1. MESH node or bridge configuration

Operate guide for Vcan1401-Mesh Ad hoc network communication module 12

2. Wireless configuration:

Operate guide for Vcan1401-Mesh Ad hoc network communication module 13

2.1 Transmission power configuration, the power of different products purchased is different.

וועג באַנדווידט: 5M 10M 20M 40M

קאַנאַל: Different channels are used to purchase different products

The coverage distance (מעטער) needs to be filled in according to the actual situation. If it is set to 3000 מעטער, it is impossible to actually run to 5000 מעטער.

Number of Antennas 2

Fixed MCS rate: Can be set to off for automatic selection. If you want stable transmission, it is recommended to set the manual, קייט (MCS0 to MCS15)

באַנדווידטה, מאָדולאַטיאָן, קורס

Limit MCS rate: It is recommended to enable it. After enabling it, if the fixed rate is MCS4, the software will automatically select the best modulation method from MCS0 to MCS4 during the test.

10ב20ב40ב
MCS0בפּסק 1/21.7ב3.3עם6.5ב13.5ב
MCS1קפּסק 1/23.2עם6.5ב13עם27עם
MCS2קפּסק 3/44.8עם9.8עם19.5ב40.5ב
MCS316קאַם 1/26.5ב13עם26ב54ב
MCS416קאַם 3/49.7ב19.5ב39ב81ב
MCS564קאַם 2/313עם26ב52עם108ב
MCS664קאַם 3/414.5ב29ב58.5ב121ב
MCS764קאַם 5/616ב32.5ב65עם135ב
MCS8בפּסק 1/23.2עם6.5ב13עם27עם
MCS9קפּסק 1/26.5ב13עם26ב54ב
MCS10קפּסק 3/49.7ב19.5ב39ב81ב
MCS1116קאַם 1/213עם26ב52עם108ב
MCS1216קאַם 3/419.5ב39ב78ב162ב
MCS1364קאַם 2/326ב52עם104ב216ב
MCS1464קאַם 3/429ב58.5ב117ב243ב
MCS1564קאַם 5/632.5ב65עם130ב270ב

From MCS0 to MCS7, two wireless ports send the same data in order to improve stability during the movement.

From MCS8 to MCS15, the two wireless ports send different data, which can make the rate X2

If it is in a mobile state, it is recommended to use BPSK or QPSK to transmit data. 16QAM and 64QAM are suitable for use with fixed transmission.

If MCS8 to MCS15 is used, it is recommended that the antennas of the two ports be 90 degrees to each other, לעמאָשל, one is vertical and the other is horizontal.

If drones are used, MCS0 to MCS2 is recommended.

The greater the bandwidth, the lower the sensitivity. The same goes for modulation.

above rate unitbps

3. נעץ:

Operate guide for Vcan1401-Mesh Ad hoc network communication module 14

4. User management:

Operate guide for Vcan1401-Mesh Ad hoc network communication module 15

5. סיסטעם

Operate guide for Vcan1401-Mesh Ad hoc network communication module 16

6. Tools Configure serial port, GPS/Beidou/GNSS, 4G/5G access and other parameters

Operate guide for Vcan1401-Mesh Ad hoc network communication module 17

6.1 Multi-device management, in the upper right corner, you can log in and manage users remotely, and it is also a real-time dynamic interface display or map display.

Operate guide for Vcan1401-Mesh Ad hoc network communication module 18
Operate guide for Vcan1401-Mesh Ad hoc network communication module 19

6.2 Serial port software settings:

WPS图片编辑

Select Expert Mode, Tools, and UART Interface.

Operate guide for Vcan1401-Mesh Ad hoc network communication module 20

choose new

Operate guide for Vcan1401-Mesh Ad hoc network communication module 21

ופמערקזאַמקייט, if you use the serial port to transmit serial data, you have to choose ttyS0 (COM1 of hardware) and ttyUSB0 (COM2 of hardware), ttyATH0 is invalid, מאָדע: נעץ

באָד קורס 115200, האַלטן ביסל 1, parity none.

נאָמען 1, protocol UDP, IP address, 192.168.55.100 (the IP address here is the IP address of the other device, לעמאָשל, input the IP of the computer for the computer, and input the IP of the device for the device).

פּאָרט 20005, 20003. Choose a port number

The computer’s IP is set to a fixed 192.168.17.100

WCAB$5]L}UUUXY@TW3U4HJB

Short the TX RX pins of COM1 and COM2 of the device.

T%$SA}H~52~8SS))})}YE0F

Use the TCP UDP test tool to fill in the IP and port of the device.