If your Lilliput GK7000 devices show the above picture of startup wrong, please try to download the factory restore firmware.

Lilliput GK7000 upgrade steps

  1. Please download the upgrade firmware from the below link. https://drive.google.com/file/d/1GYmpZkDTz4LpFseNKdakgU7Vk8ZEfHSy/view?usp=sharing
  2. Prepare a one-piece Kingston 4G SD or 8G SD card, vložte súbor "NK.bin” skopírovať na SD kartu. Poznámka: Prosím, neflashujte súbory nesúvisiace s GK-7000, inak dôjde k poškodeniu monitora.
  3. Vložte SD kartu „nk.bin“ do slotu GK7000, to give the power to GK7000. As shown in the below image, show you the upgrading progress bar. Please wait until 100%.
  4. Ak je dokončená, monitor automaticky vstúpi do systému. Potom vyberte SD kartu.
  5. Upgrade OK and you will see that it is ok now.
Lilliput GK7000 firmware recovery updating

GK-7000 Upgrade firmware download

GK-7000obnovenie predvoleného nastavenia firmvéru

How to get the printing information?

The most important step in troubleshooting is to turn on the power to obtain the RS232 serial port printing information. Then send the printed information to us for analysis.

How to operate and steps guide?

1. nastavenie

  • Download the GK-7000 serial port tool.
  • Copy the file named DNW.exe on the PC, then open this file;
  • najprv, click “Configuration → Options” on the menu and enter the settings window.
  • potom, set the COM port number (the COM port number will be decided by the COM port that RS232 connects to the PC), Prenosová rýchlosť: 115200. Download Address: 0x32000000;
  • Konečne, Click “OK” to exit this setting window.

2. Click the “Serial Port → Connect” on the menu to open the COM port.

3. Keep pressing the “ESC” key on the keyboard, v rovnaký čas, power on the
PC745/GK7000, then the DNW window will print the related information shown below.

Finish!

Najčastejšie otázky

Q1: What should I do if we downloaded and upgraded your firmware, but did not solve the problem?

A1: Please give us the serial number of every defective unit, our engineer will check the hardware and firmware version of your existing one. We will offer you the relatively upgraded firmware.

7 palcový integrovaný počítačový mobilný dátový terminál MDT Dotykový panel GK-7000

SKU: GK-7000 Kategórie: , Tagy: , ,

2 myšlienky na „Firmvér Lilliput GK7000 obnoví predvolené výrobné nastavenia, ak sa vynechá, stiahnutie softvéru núdzového riešenia"

Zanechať Odpoveď

Vaša e-mailová adresa nebude zverejnená. Povinné položky sú označené *

Discover more from iVcan.com

Ak chcete pokračovať v čítaní a získať prístup k úplnému archívu, prihláste sa na odber.

Pokračovať v čítaní

Potrebujete pomoc na WhatsApp?
Exit mobile version