Lilliput GK-7000 show error
If your Lilliput GK7000 devices show the above picture of startup wrong, please try to download the factory restore firmware.
Lilliput GK7000 upgrade steps
- Please download the upgrade firmware from the below link. https://drive.google.com/file/d/1GYmpZkDTz4LpFseNKdakgU7Vk8ZEfHSy/view?usp=sharing
- Prepare a one-piece Kingston 4G SD or 8G SD card, vložte súbor "NK.bin” skopírovať na SD kartu. Poznámka: Prosím, neflashujte súbory nesúvisiace s GK-7000, inak dôjde k poškodeniu monitora.
- Vložte SD kartu „nk.bin“ do slotu GK7000, to give the power to GK7000. As shown in the below image, show you the upgrading progress bar. Please wait until 100%.
- Ak je dokončená, monitor automaticky vstúpi do systému. Potom vyberte SD kartu.
- Upgrade OK and you will see that it is ok now.
GK-7000 Upgrade firmware download
GK-7000 | obnovenie predvoleného nastavenia firmvéru |
How to get the printing information?
The most important step in troubleshooting is to turn on the power to obtain the RS232 serial port printing information. Then send the printed information to us for analysis.
How to operate and steps guide?
1. nastavenie
- Download the GK-7000 serial port tool.
- Copy the file named DNW.exe on the PC, then open this file;
- najprv, click “Configuration → Options” on the menu and enter the settings window.
- potom, set the COM port number (the COM port number will be decided by the COM port that RS232 connects to the PC), Prenosová rýchlosť: 115200. Download Address: 0x32000000;
- Konečne, Click “OK” to exit this setting window.
2. Click the “Serial Port → Connect” on the menu to open the COM port.
3. Keep pressing the “ESC” key on the keyboard, v rovnaký čas, power on the
PC745/GK7000, then the DNW window will print the related information shown below.
Finish!
Najčastejšie otázky
Q1: What should I do if we downloaded and upgraded your firmware, but did not solve the problem?
A1: Please give us the serial number of every defective unit, our engineer will check the hardware and firmware version of your existing one. We will offer you the relatively upgraded firmware.
7 palcový integrovaný počítačový mobilný dátový terminál MDT Dotykový panel GK-7000
Lilliput GK-7000 Red light On board and yellow light on power button and no diplay show what is problm in this situation
Troubleshooting method: Please power on to obtain the RS232 serial port printing information. Send the information to us, Ďakujem. We use the information to troubleshoot problems. Navyše, please take a video for us to see, so that we can better troubleshoot the problem.
https://ivcan.com/lilliput-gk7000-firmware-recovery-the-factory-default/#How_to_get_the_printing_information