IP MESH അഡ്‌ഹോക്ക് നെറ്റ്‌വർക്ക് ഉപയോക്തൃ ഗൈഡ്

IP MESH അഡ്‌ഹോക്ക് നെറ്റ്‌വർക്ക് ഉപയോക്തൃ ഗൈഡ്

      Version number: iVcan-20230606

Brief introduction

  • Our Ad hoc network communication radio station, as a mobile self-organizing network, supports any network topology.
  • Unlike traditional wireless networks, it is a wireless broadband system with no center, distributed, multi-hop relay, dynamic routing, strong invulnerability, and good scalability.
  • Some routing protocols complete the wireless communication between nodes through wireless multi-hop forwarding.
  • An ad hoc distributed broadband wireless network transmission system with an efficient MAC layer transmission protocol and a two-layer routing protocol.
  • All nodes are completely equal, without any infrastructure, and can quickly build a dedicated self-organizing network between mobile nodes, provide instant adaptive communication, have excellent broadband performance, and support the real-time transmission of multimedia information such as video coding and audio coding.
  • The system technology has the advantages of strong anti-interference ability, high spectrum efficiency, നീണ്ട പ്രസരണ ദൂരം, anti-fading ability, and strong diffraction ability.
  • It can realize real-time and high-quality wireless two-way data transmission functions in complex and non-line-of-sight environments.

Technical Features

IP MESH Ad Hoc network
IP MESH Ad Hoc network
  • There is no need to set up a central station and complex system configuration. After the site is powered on, it will automatically form a network, and the communication can be started in “സെക്കൻഡ്”;
  • Arbitrary topology, multi-hop relay, relay forwarding;
  • The logical attributes of each node can be flexibly configured;
  • നിലവിൽ, the same frequency network can support the interconnection of ≥32 nodes;
  • The channel is encrypted with AES;
  • The system data bandwidth peak value is 90Mbps;
  • Strong anti-interference ability, high spectrum efficiency, നീണ്ട പ്രസരണ ദൂരം, വിരുദ്ധ ഇടപെടൽ
  • Strong falling ability and diffraction ability

സാങ്കേതിക പാരാമീറ്ററുകൾ

  • Communication frequency: 1412~1452MHz, adjustable in 5MHz steps;
  • ട്രാൻസ്മിഷൻ പവർ: 2*30dBm (2*1പ), 1dBm step adjustable
  • Bandwidth mode: 5 / 10 / 20 മെഗാഹെട്സ്;
  • മോഡുലേഷൻ രീതി: multi-carrier TDD-COFDM;
  • Carrier modulation: BPSK/QPSK/16QAM/64QAM (adaptive or fixed);
  • സംവേദനക്ഷമത സ്വീകരിക്കുക: -98dBm @ 10MHz;
  • Communication distance: 30കിലോമീറ്റർ (ground-air/air-air line-of-sight), 8കിലോമീറ്റർ (ground-ground line-of-sight);
  • Communication rate: peak 90Mbps (adaptive);
  • ട്രാൻസ്മിഷൻ കാലതാമസം: Single jump about 2ms
  • Multi-hop capability: വരെ കയറി 8 video jumps;
  • Start time: ≤25S;
  • Network access time: അതിൽ കുറവ് 1 രണ്ടാമത്തേത്;
  • Routing switching: അതിൽ കുറവ് 1 രണ്ടാമത്തേത്;
  • ഡാറ്റ ഇന്റർഫേസ്: network port x 2, RS232 x 2;
  • വൈദ്യുതി ഉപഭോഗം: 2~8W
  • Protection level: IP65;
  • പ്രവർത്തനം താപനില: -40~ + 70 ℃;
  • അളവുകൾ: നീളം: 72.8mm*width 47.3mm*height 17.9mm
  •  ഭാരം: 78ഗ്രാം

Software operation Instructions

Support 5M, 10എം, and 20M bandwidth, real-time graphical interface display, real-time map indication, തുടങ്ങിയവ.

The software disables DHCP by default, and the default IP address is 192.168.17.1 If you forget the address, please connect the 9th pin of the 26PIN cable to the ground to reset the parameters.

Enter the IP address of the module in the browser, and the default username and password are both admin. It takes about 20s for the module to connect to the network from power-on. The recommended browser is Chrome.

After entering, it defaults to simple mode, click expert mode to unlock more settings, suitable for professional debugging.

Status section:

IP MESH Ad Hoc network user guide 1

അവലോകനം:

IP MESH Ad Hoc network user guide 2

Topology map: (automatic refresh is turned off by default to save bandwidth, you can check automatic refresh)

IP MESH Ad Hoc network user guide 3

Check only the display path, you can know the direct jump point relationship of each module

IP MESH Ad Hoc network user guide 4

Check the details to judge the data connection status of each module. These are displayed dynamically in real time

IP MESH Ad Hoc network user guide 5

Click Details: You can know the specific situation of each module directly:

IP MESH Ad Hoc network user guide 6

Terminal state:

IP MESH Ad Hoc network user guide 7

Ad hoc network: You can remark the name, തീർച്ചയായും, it can also be operated in the terminal state.

IP MESH Ad Hoc network user guide 8

Spectrum scanning: Check the interference of each frequency band. തീർച്ചയായും, the frequency bands of different modules are purchased, and the scanning frequency bands are different.

IP MESH Ad Hoc network user guide 9

Map: (തീർച്ചയായും, to know the location information of each terminal, GNSS modules such as GPS or Beidou need to be installed)

Support tile maps, image maps, network maps, തുടങ്ങിയവ.

IP MESH Ad Hoc network user guide 10

Configuration section

മോഡ്: 1. MESH node or bridge configuration

IP MESH Ad Hoc network user guide 11

2. Wireless configuration:

IP MESH Ad Hoc network user guide 12

2.1 Transmission power configuration, the power of different products purchased is different.

ചാനൽ ബാൻഡ്വിഡ്ത്ത്: 5M 10M 20M 40M

ചാനൽ: Different channels are used to purchase different products

The coverage distance (മീറ്റർ) needs to be filled in according to the actual situation. If it is set to 3000 മീറ്റർ, it is impossible to actually run to 5000 മീറ്റർ.

Number of Antennas 2

Fixed MCS rate: Can be set to off for automatic selection. If you want stable transmission, it is recommended to set the manual, ശ്രേണി (MCS0 to MCS15)

ബാൻഡ്വിഡ്ത്ത്, മോഡുലേഷന്, നിരക്ക്

Limit MCS rate: It is recommended to enable it. After enabling it, if the fixed rate is MCS4, the software will automatically select the best modulation method from MCS0 to MCS4 during the test.

5എം10എം20എം40എം
MCS0ബ്പ്സ്ക് 1/21.7എം3.3മീറ്റർ6.5എം13.5എം
MCS1QPSK 1/23.2മീറ്റർ6.5എം13മീറ്റർ27മീറ്റർ
MCS2QPSK 3/44.8മീറ്റർ9.8മീറ്റർ19.5എം40.5എം
MCS316QAM 1/26.5എം13മീറ്റർ26എം54എം
MCS416QAM 3/49.7എം19.5എം39എം81എം
MCS564QAM 2/313മീറ്റർ26എം52മീറ്റർ108എം
MCS664QAM 3/414.5എം29എം58.5എം121എം
MCS764QAM 5/616എം32.5എം65മീറ്റർ135എം
MCS8ബ്പ്സ്ക് 1/23.2മീറ്റർ6.5എം13മീറ്റർ27മീറ്റർ
MCS9QPSK 1/26.5എം13മീറ്റർ26എം54എം
MCS10QPSK 3/49.7എം19.5എം39എം81എം
MCS1116QAM 1/213മീറ്റർ26എം52മീറ്റർ108എം
MCS1216QAM 3/419.5എം39എം78എം162എം
MCS1364QAM 2/326എം52മീറ്റർ104എം216എം
MCS1464QAM 3/429എം58.5എം117എം243എം
MCS1564QAM 5/632.5എം65മീറ്റർ130എം270എം

From MCS0 to MCS7, two wireless ports send the same data in order to improve stability during the movement.

From MCS8 to MCS15, the two wireless ports send different data, which can make the rate X2

If it is in a mobile state, it is recommended to use BPSK or QPSK to transmit data. 16QAM and 64QAM are suitable for use with fixed transmission.

If MCS8 to MCS15 is used, it is recommended that the antennas of the two ports be 90 degrees from each other, ഉദാഹരണത്തിന്, one is vertical and the other is horizontal.

If drones are used, MCS0 to MCS2 is recommended.

The greater the bandwidth, the lower the sensitivity. The same goes for modulation.

above rate unit bps

3. നെറ്റ്വർക്ക്:

IP MESH Ad Hoc network user guide 13

4. User management:

IP MESH Ad Hoc network user guide 14

5. സിസ്റ്റം

IP MESH Ad Hoc network user guide 15

6. Tools Configure serial port, GPS/Beidou/GNSS, 4G/5G access, and other parameters

IP MESH Ad Hoc network user guide 16

6.1 Multi-device management, in the upper right corner, you can log in and manage users remotely, and it is also a real-time dynamic interface display or map display.

IP MESH Ad Hoc network user guide 17
IP MESH Ad Hoc network user guide 18

6.2 Serial port software settings:

IP MESH Ad Hoc network user guide 19

Select Expert Mode, Tools, and UART Interface.

IP MESH Ad Hoc network user guide 20

choose new

IP MESH Ad Hoc network user guide 21

ശ്രദ്ധ, if you use the serial port to transmit serial data, you have to choose ttyS0 (COM1 of hardware) and ttyUSB0 (COM2 of hardware), ttyATH0 is invalid, മോഡ്: network

ബൌദ് നിരക്ക് 115200, സ്റ്റോപ്പ് ബിറ്റ് 1, parity none.

പേര് 1, protocol UDP, IP address, 192.168.55.100 (the IP address here is the IP address of the other device, ഉദാഹരണത്തിന്, input the IP of the computer for the computer, and input the IP of the device for the device).

തുറമുഖം 20005, 20003. Choose a port number

The computer’s IP is set to a fixed 192.168.17.100

IP MESH Ad Hoc network user guide 22

Short the TX RX pins of COM1 and COM2 of the device.

IP MESH Ad Hoc network user guide 23

Use the TCP UDP test tool to fill in the IP and port of the device.

Send it to loop back the data.

ഒരു മറുപടി തരൂ

നിങ്ങളുടെ ഇമെയിൽ വിലാസം പ്രസിദ്ധീകരിക്കില്ല. ആവശ്യമായ ഫീൽഡുകൾ അടയാളപ്പെടുത്തിയിരിക്കുന്നു *

ഇതിൽ നിന്ന് കൂടുതൽ കണ്ടെത്തുക iVcan.com

വായന തുടരാനും പൂർണ്ണമായ ആർക്കൈവിലേക്ക് ആക്‌സസ് നേടാനും ഇപ്പോൾ സബ്‌സ്‌ക്രൈബ് ചെയ്യുക.

തുടര്ന്ന് വായിക്കുക

WhatsApp-ൽ സഹായം ആവശ്യമാണ്?