If your Lilliput GK7000 devices show the above picture of startup wrong, please try to download the factory restore firmware.

Lilliput GK7000 upgrade steps

  1. Please download the upgrade firmware from the below link. https://drive.google.com/file/d/1GYmpZkDTz4LpFseNKdakgU7Vk8ZEfHSy/view?usp=sharing
  2. Prepare a one-piece Kingston 4G SD or 8G SD card, molim stavite datoteku “NK.bin” kopirajte na SD karticu. Белешка: Nemojte flešovati datoteke koje nisu povezane sa GK-7000, u suprotnom će oštetiti monitor.
  3. Stavite “nk.bin” SD karticu u GK7000 slot, to give the power to GK7000. As shown in the below image, show you the upgrading progress bar. Please wait until 100%.
  4. Ako se završi, monitor će automatski ući u sistem. Zatim uklonite SD karticu.
  5. Upgrade OK and you will see that it is ok now.
Lilliput GK7000 firmware recovery the factory default if missed, emergency solution software download 17
Lilliput GK7000 firmware recovery updating

GK-7000 Upgrade firmware download

ГК-7000oporavak firmvera fabrički podrazumevaniLilliput GK7000 firmware recovery the factory default if missed, emergency solution software download 18

How to get the printing information?

The most important step in troubleshooting is to turn on the power to obtain the RS232 serial port printing information. Then send the printed information to us for analysis.

How to operate and steps guide?

1. Подешавање

  • Download the GK-7000 serial port tool.
  • Copy the file named DNW.exe on the PC, then open this file;
  • Први, click “Configuration → Options” on the menu and enter the settings window.
  • Онда, set the COM port number (the COM port number will be decided by the COM port that RS232 connects to the PC), Број бауда: 115200. Download Address: 0x32000000;
  • коначно, Click “OK” to exit this setting window.
Lilliput GK7000 firmware recovery the factory default if missed, emergency solution software download 19

2. Click the “Serial Port → Connect” on the menu to open the COM port.

Lilliput GK7000 firmware recovery the factory default if missed, emergency solution software download 20

3. Keep pressing the “ESC” key on the keyboard, истовремено, power on the
PC745/GK7000, then the DNW window will print the related information shown below.

Lilliput GK7000 firmware recovery the factory default if missed, emergency solution software download 21

Finish!

Често

К1: What should I do if we downloaded and upgraded your firmware, but did not solve the problem?

А1: Please give us the serial number of every defective unit, our engineer will check the hardware and firmware version of your existing one. We will offer you the relatively upgraded firmware.

7 инчни уграђени ПЦ мобилни терминал за пренос података МДТ додирни екран ГК-7000

2 мисли о „Oporavak firmvera Lilliput GK7000 na fabričke podrazumevane vrednosti ako se propusti, preuzimanje softvera za hitne slučajeve

Оставите одговор

Ваша емаил адреса неће бити објављена. Обавезна поља су означена *

Откријте више од иВцан.цом

Претплатите се сада да бисте наставили да читате и добили приступ целој архиви.

Наставите са читањем

Потребна вам је помоћ за ВхатсАпп?