Lilliput GK7000 firmware pemulihan default pabrik jika tidak terjawab, unduhan perangkat lunak solusi darurat

Lilliput GK-7000 show error

Lilliput GK7000 firmware recovery the factory default if missed, emergency solution software download
Lilliput GK7000 firmware pemulihan default pabrik jika tidak terjawab, unduhan perangkat lunak solusi darurat

If your Lilliput GK7000 devices show the above picture of startup wrong, please try to download the factory restore firmware.

Lilliput GK7000 upgrade steps

  1. Please download the upgrade firmware from the below link. https://drive.google.com/file/d/1GYmpZkDTz4LpFseNKdakgU7Vk8ZEfHSy/view?usp=sharing
  2. Prepare a one-piece Kingston 4G SD or 8G SD card, tolong taruh filenya”NK.bin”salin ke kartu SD. Catatan: Harap jangan mem-flash file yang tidak terkait dengan GK-7000, jika tidak akan merusak monitor.
  3. Masukkan kartu SD “nk.bin” ke dalam slot GK7000, to give the power to GK7000. As shown in the below image, show you the upgrading progress bar. Please wait until 100%.
  4. Jika selesai, monitor akan secara otomatis masuk ke sistem. Kemudian keluarkan kartu SD.
  5. Upgrade OK and you will see that it is ok now.
Lilliput GK7000 firmware recovery the factory default if missed, emergency solution software download 17
Lilliput GK7000 firmware recovery updating

GK-7000 Upgrade firmware download

GK-7000pemulihan firmware default pabrikLilliput GK7000 firmware recovery the factory default if missed, emergency solution software download 18

How to get the printing information?

The most important step in troubleshooting is to turn on the power to obtain the RS232 serial port printing information. Then send the printed information to us for analysis.

How to operate and steps memandu?

1. pengaturan

  • Unduh GK-7000 serial port tool.
  • Copy the file named DNW.exe on the PC, then open this file;
  • Pertama, click “Configuration → Options” on the menu and enter the settings window.
  • Kemudian, set the COM port number (the COM port number will be decided by the COM port that RS232 connects to the PC), Tingkat Baud: 115200. Download Address: 0x32000000;
  • Akhirnya, Click “OK” to exit this setting window.
Lilliput GK7000 firmware recovery the factory default if missed, emergency solution software download 19

2. Click the “Serial Port → Connect” on the menu to open the COM port.

Lilliput GK7000 firmware recovery the factory default if missed, emergency solution software download 20

3. Keep pressing the “ESC” key on the keyboard, pada saat yang sama, power on the
PC745/GK7000, then the DNW window will print the related information shown below.

Lilliput GK7000 firmware recovery the factory default if missed, emergency solution software download 21

Finish!

FAQ

Q1: What should I do if we downloaded and upgraded your firmware, but did not solve the problem?

A1: Please give us the serial number of every defective unit, our engineer will check the hardware and firmware version of your existing one. We will offer you the relatively upgraded firmware.

7 inci Tertanam Terminal Data Seluler PC MDT Panel layar sentuh GK-7000

2 pemikiran tentang "Lilliput GK7000 firmware pemulihan default pabrik jika tidak terjawab, unduhan perangkat lunak solusi darurat

  1. familybck2023 kata:

    Lilliput GK-7000 Red light On board and yellow light on power button and no diplay show what is problm in this situation