Lilliput GK7000 firmware recovery the factory default if missed, emergency solution software download
Lilliput GK7000 firmwaregendannelse er fabriksindstillingen, hvis den savnes, download af nødløsningssoftware

If your Lilliput GK7000 devices show the above picture of startup wrong, please try to download the factory restore firmware.

Lilliput GK7000 upgrade steps

  1. Please download the upgrade firmware from the below link. https://drive.google.com/file/d/1GYmpZkDTz4LpFseNKdakgU7Vk8ZEfHSy/view?usp=sharing
  2. Prepare a one-piece Kingston 4G SD or 8G SD card, læg venligst filen "NK.bin” kopiere til SD-kortet. Bemærk: Undlad venligst at flashe filer, der ikke er relateret til GK-7000, ellers beskadiger skærmen.
  3. Sæt "nk.bin" SD-kortet i GK7000-slottet, to give the power to GK7000. As shown in the below image, show you the upgrading progress bar. Please wait until 100%.
  4. Hvis afsluttet, monitoren kommer automatisk ind i systemet. Fjern derefter SD-kortet.
  5. Upgrade OK and you will see that it is ok now.
Lilliput GK7000 firmware recovery the factory default if missed, emergency solution software download 17
Lilliput GK7000 firmware recovery updating

GK-7000 Upgrade firmware download

GK-7000firmwaregendannelse fabriksstandardenLilliput GK7000 firmware recovery the factory default if missed, emergency solution software download 18

How to get the printing information?

The most important step in troubleshooting is to turn on the power to obtain the RS232 serial port printing information. Then send the printed information to us for analysis.

How to operate and steps guide?

1. Indstilling

  • Download GK-7000 serial port tool.
  • Copy the file named DNW.exe on the PC, then open this file;
  • Først, click “Configuration → Options” on the menu and enter the settings window.
  • Derefter, set the COM port number (the COM port number will be decided by the COM port that RS232 connects to the PC), Baudrate: 115200. Download Address: 0x32000000;
  • Endelig, Click “OK” to exit this setting window.
Lilliput GK7000 firmware recovery the factory default if missed, emergency solution software download 19

2. Click the “Serial Port → Connect” on the menu to open the COM port.

Lilliput GK7000 firmware recovery the factory default if missed, emergency solution software download 20

3. Keep pressing the “ESC” key on the keyboard, på samme tid, power on the
PC745/GK7000, then the DNW window will print the related information shown below.

Lilliput GK7000 firmware recovery the factory default if missed, emergency solution software download 21

Finish!

FAQ

Q1: What should I do if we downloaded and upgraded your firmware, but did not solve the problem?

A1: Please give us the serial number of every defective unit, our engineer will check the hardware and firmware version of your existing one. We will offer you the relatively upgraded firmware.

7 tommer Integreret pc Mobildataterminal MDT Berøringsskærmpanel GK-7000

SKU: GK-7000 Kategorier: , Tags: , ,

2 kommentarer til “Lilliput GK7000 firmwaregendannelse er fabriksindstillingen, hvis den savnes, download af nødløsningssoftware

Efterlad et Svar

Din e-mail adresse vil ikke blive offentliggjort. Krævede felter er markeret *

Oplev mere fra iVcan.com

Abonner nu for at fortsætte med at læse og få adgang til det fulde arkiv.

Fortsæt med at læse

Brug for hjælp til WhatsApp?