Lilliput GK7000 ricuperazione di firmware u difettu di fabbrica si manca, Scaricamentu di u software di suluzione d'emergenza

Lilliput GK-7000 show error

Lilliput GK7000 firmware recovery the factory default if missed, emergency solution software download
Lilliput GK7000 ricuperazione di firmware u difettu di fabbrica si manca, Scaricamentu di u software di suluzione d'emergenza

If your Lilliput GK7000 devices show the above picture of startup wrong, please try to download the factory restore firmware.

Lilliput GK7000 upgrade steps

  1. Please download the upgrade firmware from the below link. https://drive.google.com/file/d/1GYmpZkDTz4LpFseNKdakgU7Vk8ZEfHSy/view?usp=sharing
  2. Prepare a one-piece Kingston 4G SD or 8G SD card, per piacè mette u schedariu "NK.bin"copia à a carta SD. Ppi: Per piacè ùn lampassi micca i fugliali chì ùn sò micca ligati à GK-7000, altrimenti dannu u monitor.
  3. Mettite a carta SD "nk.bin" in u slot GK7000, to give the power to GK7000. As shown in the below image, show you the upgrading progress bar. Please wait until 100%.
  4. Se compie, u monitor entre automaticamente in u sistema. Allora caccià a carta SD.
  5. Upgrade OK and you will see that it is ok now.
Lilliput GK7000 firmware recovery the factory default if missed, emergency solution software download 17
Lilliput GK7000 firmware recovery updating

GK-7000 Upgrade firmware download

GK-7000ripresa di firmware u difettu di fabbricaLilliput GK7000 firmware recovery the factory default if missed, emergency solution software download 18

How to get the printing information?

The most important step in troubleshooting is to turn on the power to obtain the RS232 serial port printing information. Then send the printed information to us for analysis.

How to operate and steps guida?

1. rigatura

  • Scaricate u GK-7000 serial port tool.
  • Copy the file named DNW.exe on the PC, then open this file;
  • Primu, click “Configuration → Options” on the menu and enter the settings window.
  • Allora, set the COM port number (the COM port number will be decided by the COM port that RS232 connects to the PC), Velocità Baud: 115200. Download Address: 0x32000000;
  • Infine, Click “OK” to exit this setting window.
Lilliput GK7000 firmware recovery the factory default if missed, emergency solution software download 19

2. Click the “Serial Port → Connect” on the menu to open the COM port.

Lilliput GK7000 firmware recovery the factory default if missed, emergency solution software download 20

3. Keep pressing the “ESC” key on the keyboard, in listessu tempu, power on the
PC745/GK7000, then the DNW window will print the related information shown below.

Lilliput GK7000 firmware recovery the factory default if missed, emergency solution software download 21

Finish!

Comu riggistràrisi

Q1: What should I do if we downloaded and upgraded your firmware, but did not solve the problem?

A1: Please give us the serial number of every defective unit, our engineer will check the hardware and firmware version of your existing one. We will offer you the relatively upgraded firmware.

7 inch Embedded PC Mobile Data Terminal MDT Touch screen panel GK-7000

SKU: GK-7000 Categurie: , Tags: , ,

2 penseri nantu à "Lilliput GK7000 ricuperazione di firmware u difettu di fabbrica si manca, Scaricamentu di u software di suluzione d'emergenza

  1. familybck2023 dice:

    Lilliput GK-7000 Red light On board and yellow light on power button and no diplay show what is problm in this situation

Lascià una circulacion

U vostru indirizzu email ùn serà micca publicatu. I campi obbligatori sò marcati *

Scopri di più da iVcan.com

Abbonate avà per cuntinuà à leghje è accede à l'archiviu cumpletu.

Cuntinuà à leghje

Avete bisognu di aiutu in WhatsApp?